  1. maxime.levesque

    Panel breaker sizing for a VFD (yet another question on that topic...)

    I have a 3 phase 2HP motor that draws 5.8Amps at 240v I got HuanYang VFD to drive it, with the following specs: VFD rated power: 4kW 1-phase input: 36 Amps 3-phase output: 18.5 Amps The VFD is of course oversized for the motor, the reason I got it was to have the option to upsize the motor in...
  2. F

    Rewired lathe, VFD controls via OEM controls

    Ever since I got the oil leaks fixed on my Colchester Chipmaster/Harrison 10AA and have started using it, I have daydreamed about how nice it would be to have the OEM FWD/REV/Stop buttons work as inputs to the VFD. For the last few years up through when it finally got fixed early this year, it...
  3. A

    Jacobs VFD Control System installed on PM1340GT

    I thought I would share the latest build of a “Jacobs VFD Control System”. Mark’s work and sharing of knowledge is well known to the PM owner community and others here on the Forum. Mark posted recently about his latest design iteration in this thread...